Product Description
We are offeringstate-of-the-art Industrial Scroll Chiller machines that are manufactured with high end scroll compressors acquired from danfoss-maneurop and copeland only. The gamut is offered with multiple scroll compressors in a single machine but with single refrigeration circuits, which are microprocessor based. Such kind of gamut is suitable for process cooling applications from (+) 20 Degc up to (-) 5 Deg c that reduces till (-) 50 Deg c at lower temperature. Other than this, we offer our range with a choice of using CFC free refrigerants (r-407c & r-134a). It is also available with a stainless steel chilled water expansion tank and in-built process pump. Our industrial Scroll Chilling machines are rated for an ambient of up to (+) 50 Deg c.
Our extensive range of commercial chillers feature top quality evaporators and scroll compressors. In addition, these scroll chilling machines are also well equipped with advanced safety features such as a flow switch and anti freeze protection. Designed to last, these chillers have small footprints. Specifically engineered to operate under extreme conditions, our comprehensive range is available in varied capacities, types and sustainable refrigerant options. We present you with an economical and reliable chilling technology for varied requirements of supermarkets and retail stores.
Industrial Scroll Chillers Features:
- Fully automatic /water cooled skid mounted unit
- Available in a wide capacity ranging from 1 TR to 120 TR with temperature of water/Brine being between (+) 20 C Degto(-) 5 C Deg
- The important parts are manufactured by DRYCOOL in its plant
- Main critical components of the unit is l.p/h.r switch, expansion valve and dryer of international standard
- Our control panel comes with PLC for auto operation.(optional)
- Impeccable quality product as stringent inspection & testing is done before its delivery
- 1 years guarantee with efficient customer support
- Innovative layour
- CFC free refrigerants
- Very low input KW/TR
- Sturdy construction
- Developed using state-of-art-technology
- Liquid injection for enhanced compressor life
- Heat exchanger design as per TElvlA/ASME/SEC VIII, DM, 2001
- MCS Microprocessor/PLC based/electromechanical
Major components:
- Compressor
- Water Pump
- Heat Exchanger
- Controller (Advanced temperature controller)
- Electric components like Air Switch, AC Contactor, Thermo-relay
The operating voltages of these scroll chiller machines varies between:
- 380 / 400 volt ac / 50 hz
- 460 volt ac / 50 hz
- 380 volt ac / 60 hz
- 460 volt ac / 60 hz
Design data:
- Design condensing temperature (+) 55 Degc.
- Connected power 415v ac +/- 10% / 50hz / 3 phase + neutral
- Design evaporating temperature (+) 5 Deg c.
| Industries & Applications: |
|
|
|
|
|
|
|
|
|
|
|
|
Technical Specifications:
| MODEL |
UNIT |
FSC-03A |
FSC-05A |
FSC-06A |
FSC-08A |
FSC-10A |
| CoolingCapacity |
Watts |
8250 |
11324 |
14650 |
20540 |
28400 |
| Btu/Hr |
29000 |
38650 |
50000 |
77300 |
97000 |
| Kcal/Hr |
7308 |
9740 |
12600 |
19480 |
24444 |
| RefrigerantType |
- |
R22 |
R22 |
R22 |
R22 |
R22 |
| CompressorMotor |
Kw |
2.2 |
3.3 |
4.5 |
6 |
7.5 |
| Hp |
3 |
4.5 |
6 |
8 |
10 |
| CondenserFanFlowRate |
M3/H |
2390 |
3900 |
4200 |
7800 |
9200 |
| FanDiameter |
Mm |
300*2 |
400*2 |
400*2 |
450*2 |
500*2 |
| FanPower |
Watts |
74*2 |
145*2 |
145*2 |
273*2 |
273*2 |
| WaterTankcapacity |
Liter |
65 |
65 |
65 |
140 |
220 |
| WaterPump |
Hp |
1/2 |
1/2 |
1/2 |
1 |
1 |
| Kw |
0.37 |
0.37 |
0.37 |
0.75 |
0.75 |
| FlowRate |
L/Min |
50-100 |
50-100 |
50-100 |
100-200 |
100-200 |
| RunningCurrent |
Amp |
6 |
9 |
9 |
13 |
15 |
| InsulationMaterial |
Poly-FoamTape,RubberizedTubeInsulation |
| DimensionL*W*H |
Mm |
1100*615*1080 |
1100*615*1080 |
1100*615*1080 |
1380*750*1450 |
1480*750*1450 |
| NetWeight |
Kg |
155 |
155 |
175 |
320 |
420 |

FAQ
1. What exactly is a commercial scroll chiller?
Ans - A form of cooling equipment frequently used in industrial settings is a scroll chiller. It is propelled by a compressor that pumps a refrigerant - typically a chlorofluorocarbon (CFC) - through cooling coils using a scroll-shaped compressor.
2. What benefits can industrial scroll chillers offer?
Ans - An industrial scroll chiller has several benefits over other types of chillers, including effective functioning, reduced noise levels, low maintenance needs, and a longer lifespan. They also use less energy than other varieties of chillers, which results in long-term cost benefits.
3. For what kinds of uses is an industrial scroll chiller best suited?
Ans - Applications that need a lot of cooling capacity, like air conditioning, refrigeration, and process cooling systems, are perfect for industrial scroll chillers.
4. What upkeep is necessary for a commercial scroll chiller?
Ans - An industrial scroll chiller needs routine maintenance in order to run successfully and efficiently. The compressor, condenser, evaporator, expansion valve, and oil filter are the essential parts of a scroll chiller that need to be maintained.
5. What precautions should be taken in terms of safety when using an industrial scroll chiller?
Ans - Industrial scroll chillers have dangerous chemicals in them, so extra safety measures are needed. When working with a scroll chiller, its crucial to wear safety gear and adhere to all manufacturer-provided safety guidelines. The security of all electrical connections and the proper grounding of all components must also be guaranteed.
Versatile Industrial Cooling SolutionsThis scroll chiller is engineered to cater to a wide spectrum of industrial applicationsranging from pharmaceutical processing and chemical production to plastics, die mould cooling, and HVAC systems. Its reliable performance supports continuous operations, making it especially valuable for critical manufacturing environments.
Robust Construction for ReliabilityManufactured with powder coated galvanized steel and a copper cooling coil, the chiller promises resistance to wear and corrosion. Stainless steel nozzles further amplify operational longevityensuring years of service even under strenuous operating conditions and demanding industrial loads.
Energy Efficient and User FriendlyEquipped with a high-efficiency scroll compressor and a 2 HP water pump motor, this chiller balances performance with energy savings. Its compact dimensions and intuitive design enable straightforward setup and integration within new or existing facilities, reducing installation downtime.
FAQs of Industrial Scroll Chillers:
Q: How does the industrial scroll chiller enhance cooling efficiency in industrial processes?
A: The scroll chiller features a high airflow (5,500 m/h) and water flow rate (4.5 m/h), ensuring rapid heat removal and consistent temperature control across various industrial systems. Such efficiency is essential for processes in pharmaceuticals, plastics, and chemical industries.
Q: What are the typical applications for this scroll chiller model?
A: This chiller is ideally used in industrial process cooling, HVAC, pharmaceutical manufacturing, chemical processing, and cooling of plastic die molds. Its 25 TR refrigerating capacity allows for versatile use across diverse sectors requiring robust thermal management.
Q: When should you choose a scroll chiller with 25 TR capacity?
A: A 25 TR capacity unit is ideal when your facility requires consistent, medium-to-large scale coolingwhether for continuous manufacturing processes or to stabilize environments in HVAC systems. Its a suited option for facilities processing significant thermal loads.
Q: Where can this scroll chiller be installed for best performance?
A: Install the chiller in a well-ventilated technical area, ensuring easy access for maintenance and proximity to the systems requiring cooling. Both indoor and outdoor installations are possible, depending on your cooling type (air or water cooled) and facility layout.
Q: What materials are used in the construction of the chiller, and what benefits do they offer?
A: The main structure is built from powder coated galvanized steel, providing corrosion resistance and toughness. The cooling coil is copper, promoting excellent thermal conductivity, while stainless steel nozzles resist rustoffering durability and long-term performance.
Q: How easy is the chiller to integrate into existing industrial systems?
A: Thanks to its standard electrical requirements (3 phase, 415 V, 50 Hz) and moderate dimensions (2200x950x1500 mm), installation is straightforward. Its designed for compatibility with new as well as retrofit applications, ensuring a hassle-free integration process.